    Brand Name : Supmeter
    Model Number : BST106-M10(AL)
    Certification : CE
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 10000pcs/week
    Delivery Time : 1-5days
    Price : Negotiation
    MOQ : 1pcs
    • Product Details
    • Company Profile

    Single Scale Organic Fertilizer Packing Scales Indicator, Single scale

    Single Hopper 10-50kg Organic Fertilizer Packing Scale Indicator, Weighing Hopper Instrument Scale for Grain Packing


    Main Features:

    ² Suitable for Ration Packing Scale with optional Hopper-weighing Mode, Bag-weighing Mode and Loss-in-weight Mode.

    ² EMC design with high anti-jamming capability, suitable for industrial environment.

    ² Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.

    ² 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.

    ² Loadcell Interface

    l Max. Connection Quantity: 16 Loadcells (350Ω).

    l 24-bit High-precision and high-speed ∑-A/D conversion module with 1/1,000,000 internal resolution and samplingfrequency 800Hz.

    l Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strongvibration on the load receptor, and the rapid response capability when the weight signal changes.

    ² I/O Interface

    l 9 Definable normally open switch inputs [DI] and 18 definable normally open transistor switch outputs [DO].

    l Optional ‘High/Medium/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.

    l 2 Definable analog signal AOs[0~10V] for weight signal output or High/Medium/Low Speed Feed control.

    ² Digital Communication Interface

    l COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.

    l COM[RS232] for connecting RS232 Serial Printer.


    Button Operation

    NameOperationState IndicatorAuthorization
    【Auto】Auto / Manual [Emergency Stop] switch.

    Green: Auto state.

    Grey: Manual state.

    All Users
    【Start】Start.

    Green: Running state.

    Grey: Stop state.

    【Re-run】Clear Alarm & Recover Running.
    【Stop】

    Normal Stop [Last Batch].

    Stop after the present batch finished.

    Flashing Red.
    【E-Stop】Emergency Stop.
    【Alarm】

    Alarm Query / Clear Alarm.

    ‘Auto/Pause’ state: Recover Running after alarms cleared.

    Red: Alarm state.
    【Print】

    Report Print:

    • [ Auto Print]: Print Batch Records.
    • [Total]: Print Totalizing Report.
    • [Recipe]: Print Working Recipe.
    【Lock】

    Screen-locking: Locking/unlocking the operating buttons of main user interface.

    Auto Screen-locking: Refer to parameter [901].

    Flashing Red: Locked.

    Grey: Unlocked.

    【Menu】Enter Main Menu.
    【User】User Login. Display: Operator / Engineer / Admin.
    【Zero】Manual Zero [No Power-down Protection].Flashing green.
    【Bag】Bag-clamp/release Request.

    Green: Bag-clamping state.

    Grey: Bag-releasing state.

    【Bulk】Manual Start/Stop Bulk Feed.Green: Working state.
    【Med】Manual Start/Stop Medium Feed.
    【Drip】Manual Start/Stop Dribble Feed.
    【Dump】Manual Start/Stop Dumping.
    【Mat.】Manual Start/Stop Supplying Materials into Feeding Bin.Flashing green.
    【Clear】Clear Screen: Clear the display values of Feeding Weight, Totalized Weight, Batch Count and Cycle Speed.

    Engineer

    Administrator


    Error Messages

    MessageAlarm CauseSolution
    RAM FaultThe chip RAM is damaged.Replace the chip RAM.
    EEPROM FaultThe chip EEPROM is damaged.Replace the chip EEPROM.
    Parameter ErrorThe chip EEPROM is damaged.Replace the chip EEPROM.
    Weighing Signal ErrorWeighing signal reversed or not connected.Connect the loadcell correctly.
    ADC FaultThe chip ADC is damaged.Replace the ADC module.
    Over ADC RangeWeighing signal exceeds A/D conversion range.

    1. Check if the loadcell is connected.

    2. Check if the capacity of loadcell is too small.

    3. Check if the loading weight is too big.

    Overload AlarmWeight > (Scale Capacity + 9 × Scale Division).

    1. Check if the set value of parameter [102] ‘Scale Capacity’ is reasonable.

    2. Check if the loadcell is connected.

    3. Check if the capacity of loadcell is too small.

    4. Check if the loading weight is too big.

    Internal Data-bus FaultPlease contact manufacturer.