    Brand Name : Supmeter
    Model Number : BST106-M10(FL)
    Certification : CE
    Price : 210-330usd/pcs
    Payment Terms : T/T, Western Union, L/C
    Supply Ability : 5000pcs/month
    Delivery Time : 3-10 working days
    MOQ : 1pcs
    • Product Details
    • Company Profile

    Medicine Bottle Filling Machine Indicator, Liquid Filling Weighing Controller CE Certified

    Medicine Bottle Filling Machine Indicator, Liquid Filling Weighing Controller CE Certified

    • Suitable for Liquid/Gas/Powder Ration Fillingweigher [1-Scale].
    • Optional filling modes: Fill on Drum’s Top / Fill on Drum’s Bottom / Step-fill from Drum’s Bottom.
    • EMC design with high anti-jamming capability, suitable for industrial environment.
    • Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
    • 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
    • Loadcell Interface
    • Max. Connection Quantity: 16 Loadcells (350Ω).
    • 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 800Hz.
    • Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
    • I/O Interface
    • 9 Definable normally open switch inputs [DI] and 12/18 definable normally open transistor switch outputs [DO].
    • Optional ‘Bulk/Medium/Dribble Fill’ DOs for filling control. Optional Continuous and Jogging Dribble Fill Methods.
    • 2 Optional&definable analog signal AO[0~10V] for weight signal output or ‘Bulk/Medium /Dribble Fill’ control.
    • Digital Communication Interface
    • COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
    • COM[RS232] for connecting RS232 Serial Printer.
    • USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
    • LAN: Optional Ethernet port.


    User Login Interface

    NameOperationNote
    【Login】

    User Login.

    Exfactory Passwords:

    • Operator: None.
    • Engineer: 0.
    • Administrator: 1.
    Operation ‘Main Menu / F5 User / Password / PSW Set’ for Modifying Password.
    【User Name】After password inputted, the matching User Name will be displayed.
    • Operator: User with lowest authorization.
    • Engineer: User with higher authorization.
    • Administrator: User with highest authorization.
    【Operate】Enter ‘Main User Interface’.Operation ‘Main Menu / F5 User / Password / Login [Logoff]’ for Re-login and Logoff.

    Button Operation

    NameOperationState IndicatorAuthorization
    【Auto】Auto / Manual [Emergency Stop] switch.

    Green: Auto state.

    Grey: Manual state.

    All Users
    【Start】Start.

    Green: Running state.

    Grey: Stop state.

    【Stop】Stop [Valid at Auto-running state].
    【Re-run】Clear Alarm & Recover Running.
    【E-stop】Emergency Stop.
    【Alarm】

    Alarm Query / Clear Alarm.

    ‘Auto/Pause’ state: Recover Running after alarms cleared.

    Red: Alarm state.
    【Print】Report Print.Green: Auto Print is allowed.
    【Lock】

    Screen-locking: Locking/unlocking the operating buttons of main user interface.

    Auto Screen-locking: Refer to parameter [901].

    Flashing Red: Locked.

    Grey: Unlocked.

    【Menu】Enter Main Menu.
    【User】User Login. Display: Operator / Engineer / Admin.
    【Lower】Manual Lower Filling Gun.Flashing Green: Filling Gun is moving down.
    【Lift】Manual Lift Filling Gun.Flashing Red: Filling Gun is moving up.
    【Bulk】Manual Start/Stop Bulk Fill.Green: Working state.
    【Med】Manual Start/Stop Medium Fill.
    【Drip】Manual Start/Stop Dribble Fill.
    【Zero】Manual Zero [No Power-down Protection].Flashing Red.
    【Tare】Manual Tare [No Power-down Protection].Flashing Red.
    【Clear】Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count.

    Engineer

    Administrator