    Brand Name : Supmeter
    Model Number : BST106-H18
    Certification : CE
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 1000pcs/month
    Delivery Time : 3-10 working days
    • Product Details
    • Company Profile

    VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm

    VFD Ration Batching Controller Digtal Weight Indicator For 5-Material Ration Batching Scale


    Main Features:

    • Suitable for Ration Batching Scale with 5-Material&2-Speed Feeding [Single-Scale Mode].
    • EMC design with high anti-jamming capability, suitable for industrial environment.
    • 32-bit ARM CPU with 72MHz clock & higher arithmetic speed.
    • 6+10 green VFD digital tubes for English character and digit display.
    • 8-key English keypad.
    • Menu&Shortcut mode operation with key tone.
    • 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 400Hz.
    • Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
    • Max. Connection Quantity: 8 Loadcells (350Ω).
    • Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
    • Optional Data Calibration function.
    • Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
    • 7 Normally open switch inputs [DI] and 12 normally open transistor switch outputs [DO].
    • Optional ‘High/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
    • 1 Optional and definable analog signal AO[4~20mA] for weight signal output or ‘High/Low Speed Feed’ control.Optional ‘Fall Value Auto Correction’ function.
    • 10 Recipes for batching control.
    • Optional ‘Fall Value Auto Correction’ function.
    • Optional ‘Auto Pause for Deviation Alarm’, ‘Auto Pause for Gross Weight Upper Limit Alarm’ and ‘Manual Pause’ functions.
    • Optional ‘Target Batch Control’ function [With Target Batch Count finished, the batching process will stop automatically].
    • ‘Batching Process Power-off Protection’ function available.
    • 2 Optional communication ports for connecting Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
    • The present Batch Record can be printed automatically and manually.
    • 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
    • With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.

    Pictures


    Technical Specification

    • Executing Standard
    • CMC GB/T 7724-2008PRC National Standard.
    • OMIL R76: 2006International Recommendation.
    • Accuracy Grade: III.
    • Verification Accuracy: 0.02%.
    • Static Weighing Accuracy: 0.2%~0.5%.
    • Batching Accuracy: 0.2%~0.5%.
    • Display
    • 6+10 Green VFD digital tubes for English character and digit display.
    • Weight Display Range: -99,999~+999,999.
    • Scale Capacity: Setting Range 1~999,999.
    • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
    • Display Resolution: 1/100,000.
    • Weight Unit: Optional kg, t, g, none.
    • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
    • Display Refreshing Time: Setting Range 0.01~1.00s.
    • Kaypad
    • 8-key English keypad.
    • Menu&Shortcut mode operation with key tone.
    • Loadcell Interface
    • Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
    • Signal Input Range: 0~25mV.
    • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
    • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
    • Sampling Frequency: 400Hz.
    • Special anti-vibration digital filtering algorithm.
    • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
    • Gain Drift: ±5ppm/℃.
    • Non-linearity: 0.005%FS.
    • Switch&Analog Signal Interface
    • 7 Normally Open Switch Inputs [DI].
    • 12 Normally Open Transistor Switch Outputs [DO]: DC24V, 500mA.
    • 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.
    • Digital Communication Interface
    • COM1: RS232.
    • COM2 Optional: RS232/RS485/RS422/Profibus-DP/Ethernet modules.
    • Connectable: Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
    • Report Print
    • The present Batch Record can be printed automatically and manually.
    • 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
    • Operating Specification
    • Optional Operating Voltage
    • Operating Voltage 1: DC24V±20%.
    • Operating Voltage 2: AC85~264V, 50/60Hz.
    • Operating Voltage 3: AC220V±15%, 50/60Hz.
    • Free to configure one of them.
    • Max. Power Consumption: 10W.
    • Outline Size
    • Model Panel-mounting: 164×82×188mm [W×H×D].
    • Model Explosion-proof: 340×390×205mm [W×H×D].
    • Panel Cut-out Size
    • Model Panel-mounting: 153×77mm [W×H].
    • Operating Temperature: -25℃ to +45℃.
    • Storage Temperature: -30℃ to +60℃.
    • Relative Humidity: Max. 85%RH.
    • Application Environment of Model Explosion-proof
    • Explosion gas environment: Zone 1&2.
    • Classes of explosion gas mixture: IIA, IIB.
    • Temperature grades of explosion gas mixture: T1~T6.
    • Ex-mark: Ex d IIB T6 Gb.
    • Protection Level
    • Front Panel of Model Panel-mounting: IP65.
    • Model Explosion-proof: IP65.
    • Weight
    • Model Panel-mounting: Approx. 1.6kg.
    • Model Explosion-proof: Approx. 19.2kg.

    Model Panel-mounting Operation Interface


    Keypad Operation


    If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.


    Menu Operation
    Key NameDescription
    【MENU】Enter Main Menu / Exit.
    【ENT】Enter / Save / Alarm Acknowledge.
    【◄】Cursor shifts left.
    【►】Cursor shifts right.
    【▲】

    Display the previous interface or option.

    Digit input: +1.

    【▼】

    Display the next interface or option.

    Digit input: -1.

    Quick Operation

    【Ñ】

    *

    • Key-locking.
    • Key-unlocking.
    【SET】M1~M5 Target Values setting.
    【G/N】Gross Weight / Net Weight display switch.

    【→C←】

    【CAL】

    *

    Load Calibration.

    【→0←】

    【ZERO】

    *

    • [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
    • [≡ZEro≡] Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
    • The controller will switch to Gross Weight display.

    【→T←】

    【TARE】

    *

    • [≡tArE≡]: Manual Tare without Power-down Protection.
    • [-PStr-]: Preset Tare Weight with Power-down Protection.
    • [-rStr-]: Clear Tare Weight with Power-down Protection.
    • The controller will switch to Net Weight display.
    【,】*Record Query.
    【/】*Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count.
    【‡】*Time display and setting.
    【±】‘+’/‘-’ switch.
    【6】

    Main Display Interface:

    • [bAt.tAb]: Print Present Batch Record.
    • [tot.tAb]: Print Totalizing Report.
    • [SEt.tAb]: Print Present Recipe.

    Record Query state: Print Historical Batch Record.

    【ENT】

    Pause State:

    • [Cont]: Recover Running.
    • [StoP]: Stop.

    *: Keep the key pressed for 2 seconds.


    State Indication


    SignDescription
    [GROSS]Gross Weight display.
    [NET]Net Weight display.
    [LOCK]

    ON: Key-locked.

    OFF: Key-unlocked.

    [◣◢]Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’.
    [→0←]The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’.
    [kg/t/g]Weight unit.
    [ NUM]Material No. display.
    [ PCS]Batch Count display.
    [TOT]

    Totalized Weight display.

    Total Feeding Weight display.

    [SET]

    Target Value display.

    Parameter setting state.

    [RUN]

    ON: Running state.

    Blinking: Pause state.

    OFF: Stop or Calibrating state.

    [ZERO]Net Weight ≤ Non-load Zero Range.
    [NZ]It’s allowed to do Zero Fine Adjustment.
    [SP1]High-speed Feeding.
    [SP3]Low-speed Feeding.
    [FILL]Stop state: Weight value is increasing.
    Running state: It’s in the feeding process.
    [COMP]

    ON: It’s doing comparation between Feeding Weight and Target Value.

    OFF: It turns off in Comparing-prohibited Time.

    [DEV]Positive/Negative Deviation Alarm.
    [FALL]ON: Fall Value Auto Correction function is open.
    [DISC]Stop state: Weight value is reducing.
    Running state: It’s in the dumping process.
    [HH]Gross Weight Upper Limit Alarm.

    Model Panel-mounting Installation

    Model AC85~264V/AC220V Terminal

    System Diagram for M1~M5 Ration Batching System


    Quality VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
    *Subject:
    *Message:
    Characters Remaining: (0/3000)