Sign In | Join Free | My himfr.com
Home > Electronic Weighing Indicator >

Measurement Control System Electronic Weight Indicator With Display Holding

    Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers
     
    Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers
    • Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers
    • Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers
    • Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers
    • Buy cheap Measurement Control System Electronic Weight Indicator With Display Holding from wholesalers

    Measurement Control System Electronic Weight Indicator With Display Holding

    Ask Lasest Price
    Brand Name : Supmeter
    Model Number : BST106-B60(F)
    Certification : CE
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 2000pcs per month
    Delivery Time : 1-20 working days
    • Product Details
    • Company Profile

    Measurement Control System Electronic Weight Indicator With Display Holding

    Force Measuring Controller Electronic Weighing Indicator With Display Holding And DO Alarm Output


    Technical Specification

    • Executing Standard
    • CMC GB/T 7724-2008PRC National Standard.
    • OMIL R76: 2006International Recommendation.
    • Accuracy Grade: III.
    • Verification Accuracy: 0.03%.
    • Static Force Measuring Accuracy: 0.2%~0.5%.
    • Display
    • 6+8 Red LED digital tubes for English character and digit display.
    • Force Value Display Range: -60,000~+60,000.
    • Force Capacity: Setting Range 1~60,000.
    • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
    • Display Resolution: 1/60,000.
    • Force Value Unit: Optional kg, t, g, none.
    • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
    • Display Refreshing Time: Setting Range 0.01~1.00s.
    • Kaypad
    • Model Panel-mounting: 4-key English keypad.
    • Model Explosion-proof: 6-key English keypad.
    • Menu&Shortcut mode operation with key tone.
    • Loadcell Interface
    • Excitation Voltage/Max. Current: DC9V/120mA [4-350Ω loadcells].
    • Signal Input Range: -22.5~+22.5mV.
    • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
    • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
    • Sampling Frequency: 3200Hz.
    • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
    • Gain Drift: ±5ppm/℃.
    • Non-linearity: 0.005%FS.
    • Switch/Analog Signal Interface
    • 6 Normally Open Switch Inputs [DI].
    • 5 Normally Open Relay Switch Outputs [DO]: AC250V/DC24V, 1A.
    • 1 Optional&Definable Analog Signal Output: 4~20mA, Non-linearity: 0.05%FS.
    • Digital Communication Interface
    • COM1: RS232.
    • COM2: RS485.
    • Connectable: Host IPC/PLC and LED Remote Display.

    • Operating Specification
    • Operating Voltage
    • Model Panel-mounting: DC24V±20%.
    • Model Explosion-proof: AC110~240V, 50/60Hz.
    • Max. Power Consumption: 5W.
    • Outline Size
    • Model Panel-mounting: 110×62×150mm [W×H×D].
    • Model Explosion-proof: 256×290×166mm [W×H×D].
    • Panel Cut-out Size
    • Model Panel-mounting: 94×47 mm [W×H].
    • Operating Temperature: -25℃ to +45℃.
    • Storage Temperature: -30℃ to +60℃.
    • Relative Humidity: Max. 85%RH.
    • Application Environment of Model Explosion-proof
    • Explosion gas environment: Zone 1&2.
    • Classes of explosion gas mixture: IIA, IIB.
    • Temperature grades of explosion gas mixture: T1~T6.
    • Ex-mark: Ex d IIB T6 Gb.
    • Protection Level
    • Front Panel of Model Panel-mounting: IP65.
    • Model Explosion-proof: IP65.
    • Weight
    • Model Panel-mounting: Approx. 0.5kg.
    • Model Explosion-proof: Approx. 9.2kg.


    Model Panel-mounting Operation Interface


    Keypad Operation

    If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.


    Menu Operation
    Key NameDescription
    【MENU】

    Enter Main Menu.

    Exit.

    【ENT】Enter / Save / Alarm Acknowledge.
    【◄】

    Cursor shifts left.

    Display the previous option.

    【►】

    Cursor shifts left.

    Display the next option.

    【▲】

    Display the next interface or option.

    Digit input: +1 ( 0~9 loop).

    【▼】

    Display the previous interface or option.

    Digit input: -1 ( 0~9 loop).

    Quick Operation

    【MENU】

    【Ñ】

    *

    • Key-locking.
    • Key-unlocking.

    【◄】

    (【SET】)

    Setpoint parameters setting.

    【◄】

    【ZERO】

    【→0←】

    *

    • [-ZEro-]: Zero Calibration with Power-down Protection.
    • [≡ZEro≡]: Zero Fine Adjustment without Power-down Protection.

    【ENT】

    (【CLS】)

    *

    Clear Screen: Clear the display value of Peak Hold Value.

    *: Keep the key pressed for 2 seconds.


    DI/DO Connection for DI Switch & DI Jump Start&Stop Mode